542 |
-402 |
Shuttle Travel Drive Fault |
|
544 |
-314 |
pallet over hanging |
|
554 |
-304 |
Loading timeout. Pallet twisted or stuck. |
|
318 |
-272 |
Full-On-Full 3 time, the stacker sensors need to be checked. |
|
75 |
-235 |
Z axis Software limit reached
|
|
74 |
-234 |
Z axis position not reach in given time
|
|
73 |
-233 |
Z axis counter block
|
|
72 |
-232 |
Z axis run away
|
|
71 |
-231 |
Z axis Trajectory error
|
|
70 |
-225 |
Y axis Software limit reached
|
|
69 |
-224 |
Y axis position not reach in given time
|
|
68 |
-223 |
Y axis counter block
|
|
67 |
-222 |
Y axis run away
|
|
66 |
-221 |
Y axis Trajectory error
|
|
65 |
-215 |
X axis Software limit reached
|
|
64 |
-214 |
X axis position not reach in given time
|
|
63 |
-213 |
X axis counter block
|
|
62 |
-212 |
X axis run away
|
|
61 |
-211 |
X axis Trajectory error
|
|
305 |
-194 |
Communication Error on Slave Exit PLC |
|
306 |
-193 |
Communication Error on Wrapper PLC |
|
304 |
-192 |
Communication Error on Exit PLC |
|
59 |
-191 |
PLC for Q1 is offlined. All missions are suspended
|
|
199 |
-185 |
Communication between PC and Machine is broken |
|
56 |
-184 |
Serial send cannot be accepted by machine
|
|
200 |
-183 |
The attampt of PC sending message to the machine is failed |
|
55 |
-182 |
Serial communication to the machine is lost
|
|
54 |
-181 |
Serial connection to the machine is lost
|
|
218 |
-180 |
Machine Offlined or Serial port is missing |
|
53 |
-153 |
Machine CNC fault
|
|
50 |
-136 |
Wrong pallet measurment
|
|
49 |
-135 |
Trans on Trdk pos not ok
|
|
48 |
-134 |
Stacker not on board
|
|
46 |
-132 |
Motor Switch Broken Off
|
|
45 |
-131 |
Open Gates
|
|
42 |
-128 |
Emergency
|
|
37 |
-123 |
Obstacle in the Pathway
|
|
36 |
-122 |
Forks blocking Entry Gate
|
|
35 |
-121 |
Forks blocking Exit Gate
|
|
34 |
-120 |
forks blocking Lift Path
|
|
33 |
-119 |
Stacker forks are out of position
|
|
32 |
-118 |
Timeout of Position Pin
|
|
31 |
-117 |
Timeout of Lift
|
|
30 |
-116 |
Timeout at Transport
|
|
29 |
-115 |
Timeout of Transpt Rolls
|
|
28 |
-114 |
Timeout: Transferdeck Chain not moving due to bad Pallet or Pallet Sensor position
|
|
27 |
-113 |
timeout of Forks/Bridges
|
|
26 |
-112 |
handshake Signals Missed
|
|
25 |
-111 |
Lost LU
Unkwon pallet on borad or Sensor mis-read |
|
24 |
-110 |
Unkown pallet on board or Sensor issue |
|
23 |
-109 |
LU Not Aboard
|
|
20 |
-106 |
Misplaced LU
|
|
19 |
-105 |
Unknown LU Aboard
|
|
18 |
-104 |
Unloading fault: Pallet cannot be unload
|
|
219 |
-103 |
loading fault: Error at loading
|
|
267 |
-99 |
E-stop pushed or Limit switch reached |
|
295 |
-98 |
TD pin not down |
|
493 |
-97 |
Spare |
|
492 |
-94 |
PC communication between PC and SC-6 PLC is lost |
|
491 |
-93 |
PC communication between PC and NC PLC is lost |
|
490 |
-92 |
PC communication between PC20 and L2PC is interupted |
|
201 |
-91 |
PC/PLC Communication Error |
|
296 |
-88 |
Database connection lost |
|
540 |
-84 |
Duplicate pallet number detected. Please scan again.. |
|
489 |
-83 |
The pallet # is not accepted. Please make sure you scan the correct barcode. |
|
488 |
-82 |
The overhead scanner cannot read this pallet, please try the hand-held scanner |
|
487 |
-81 |
90" cell is running out. Use Function to Pass and STOP 90" Pallet Entry Immediately |
|
266 |
-67 |
Cross beam blocked |
|
265 |
-65 |
Onboard pallet is missing |
|
264 |
-63 |
Unknown pallet on board |
|
263 |
-61 |
Pallet still on board after unloading |
|
262 |
-59 |
Pallet crooked or sensor issue |
|
261 |
-57 |
Object on board after Fork extended |
|
260 |
-55 |
Forks are not at center position |
|
259 |
-53 |
Cross beam blocked Right side |
|
258 |
-51 |
Cross beam blocked Left side |
|
486 |
-35 |
Spare |
|
485 |
-34 |
Spare |
|
257 |
-31 |
Hoise Brake Y did not operate after 6 tries |
|
256 |
-30 |
Travel Brake X did not operate after 6 tries |
|
255 |
-26 |
Stacker "Full-on-Full" 5 times. Please check the sensor., |
|
254 |
-25 |
Forks not in center position |
|
253 |
-23 |
Forks not in center position |
|
252 |
-22 |
The cell is disabled |
|
251 |
-21 |
The cell is disabled |
|
250 |
-19 |
Hoist Y motor overheating. Please wait to let it cooling down |
|
249 |
-18 |
X1/X2 motor overheating. Please wait to let it cooling down |
|
248 |
-16 |
Hoist Brake Y failed in auto run |
|
247 |
-15 |
Hoist Brake Y contactor not operate |
|
246 |
-14 |
Travel Brake X2 did not operate in auto run |
|
245 |
-13 |
Travel Brake X did not operate in auto run |
|
244 |
-12 |
X or Y brake did not operate in 6 attampts |
|
243 |
-11 |
Hoise Y position reached low limit |
|
242 |
-10 |
Hoise Y position reached high limit |
|
241 |
-9 |
Travel X position reached low limit |
|
240 |
-8 |
Travel X position reached high limit |
|
239 |
-7 |
Hoise Encoder Y fault |
|
238 |
-6 |
Travel Encode fault |
|
237 |
-5 |
Infeed not ready |
|
236 |
-4 |
Forks drive Z fault |
|
235 |
-3 |
Hoist drive Y fault |
|
234 |
-2 |
Travel drive X2 fault |
|
233 |
-1 |
Travel drive X1 fault |
|
346 |
0 |
|
|
1 |
1 |
Waiting For Command
|
|
2 |
2 |
Waiting For Replacement
|
|
3 |
3 |
Moving To Source
|
|
4 |
4 |
Moving To Destination
|
|
5 |
5 |
Moving To Home
|
|
6 |
6 |
Climbing Up Transfer Deck
|
|
7 |
7 |
Moving Between Isles
|
|
8 |
8 |
Loading Pallet
|
|
9 |
9 |
Unloading Pallet
|
|
10 |
10 |
End Of Operation
|
|
11 |
11 |
Operation Aborted
|
|
12 |
12 |
Request of Abort Command
|
|
13 |
13 |
Pallet In Reverse Gear
|
|
14 |
14 |
Stacker Crane Aboard
|
|
319 |
15 |
Putting the pallet down ... |
|
320 |
17 |
Retracting Froks to center at the Destination ... |
|
321 |
20 |
@F1: The mission is completed |
|
184 |
21 |
X Axis Trajectory Error |
|
185 |
22 |
X Axis Run away |
|
186 |
23 |
X Axis Counter block |
|
187 |
24 |
X Axis Position not reached in give time |
|
188 |
25 |
X Axis Software limit reached |
|
322 |
26 |
Spare |
|
323 |
27 |
Spare |
|
189 |
31 |
Y Axis Trajectory Error |
|
190 |
32 |
Y Axis Run away |
|
191 |
33 |
Y Axis Counter block |
|
192 |
34 |
Y Axis Position not reached in give time |
|
193 |
35 |
Y Axis Software limit reached |
|
194 |
41 |
Z Axis Trajectory Error |
|
195 |
42 |
Z Axis Run away |
|
196 |
43 |
Z Axis Counter block |
|
197 |
44 |
Z Axis Position not reached in given time |
|
198 |
45 |
Z Axis Software limited reached |
|
324 |
46 |
Pallet is ready for Entry UDC assignmnt |
|
325 |
47 |
No stacker bay available for Entry assignment |
|
326 |
48 |
You cannot not run a function move when stacker is in Auto mode. Switch it to Manual and try it again. |
|
327 |
49 |
ReSend ... |
|
328 |
50 |
Insert Pallet data into database |
|
329 |
51 |
nor used |
|
495 |
52 |
not used |
|
330 |
53 |
Waiting for UDC assignment ... |
|
331 |
54 |
Waiting for PLC acknowledgement ... |
|
494 |
55 |
... |
|
332 |
60 |
South Entry 1 |
|
333 |
61 |
Verifying Pallet Length and Height @ South Entry 1 |
|
334 |
62 |
Verifying Pallet length and Height @ South Entry 1 |
|
335 |
63 |
providing pallet data to L2 PC @ South Entry 1 |
|
336 |
64 |
Empty Pallet # for Entry pallet at South Entry 1 |
|
337 |
65 |
Resend pallet data to L2 PC @ South entry 1 |
|
338 |
69 |
Pallet data is processed sucessfully @ South entry 1 |
|
339 |
70 |
Insert Pallet data at South Entry 5 |
|
340 |
71 |
Verifying Pallet Length and Height @ South Entry 5 |
|
341 |
72 |
Verifying Pallet length and Height @ South Entry 5 |
|
342 |
73 |
South Entry 5 |
|
343 |
74 |
Empty Pallet # for Entry pallet at South Entry 5 |
|
344 |
75 |
Resend pallet data to L2 PC @ South entry 5 |
|
345 |
79 |
Pallet data is processed sucessfully @ South entry 5 |
|
347 |
83 |
South Exit bay hand shake sensor not read (122) |
|
202 |
92 |
PC/PLC Communication issue recovered |
|
15 |
100 |
Fault list no content |
|
16 |
101 |
Source Empty
|
|
17 |
102 |
Target Full
|
|
348 |
103 |
Hoist (Y) motor over temperature |
|
349 |
104 |
Travel (X1) motor temperature OK |
|
350 |
105 |
Travel (X2) motor temperature OK |
|
351 |
106 |
Hoist (Y) motor temperature OK |
|
21 |
107 |
Oversized LU
|
|
22 |
108 |
LU Still Aboard
|
|
352 |
109 |
Travel (X1/X2) motor fans off |
|
353 |
110 |
Hoist (Y) motor fan off |
|
354 |
111 |
Forks (Z) motor over temperature |
|
355 |
112 |
Forks (Z) motor temperature OK |
|
356 |
113 |
Target not reached |
|
357 |
114 |
Travel (X) or Hoist (Y) brake did not open before a motion starts |
|
358 |
115 |
The UDC is not in Stacker, Request a resend |
|
359 |
116 |
Travel (X1) brake did not open, reset it automatically ...... |
|
360 |
117 |
Travel (X2) brake did not open, reset it automatically ...... |
|
361 |
118 |
Hoist (Y) brake did not open, reset it automatically ...... |
|
362 |
119 |
X travel brake did not open indicated by the limit switch on motor |
|
363 |
120 |
Spare |
|
364 |
121 |
North entry bay hand shake sensor not ready |
|
365 |
122 |
Exit bay hand shake sensor not ready |
|
366 |
123 |
Pallet scanned by Hand-head scanner |
|
38 |
124 |
Source Unknown
|
|
39 |
125 |
Sledge Not Empty
|
|
40 |
126 |
Sledge Empty
|
|
41 |
127 |
Error At Transit
|
|
43 |
129 |
Generic Warning
|
|
44 |
130 |
Error At Vertical Elevet
|
|
367 |
131 |
[Manu] is clicked by PC user |
|
368 |
132 |
[Auto] is clicked by PC user |
|
47 |
133 |
Abort UDC on machine
|
|
369 |
134 |
[Reset] is clicked BY PC user |
|
370 |
135 |
Manual button on staker is pushed down |
|
371 |
136 |
Manual button on stacker is released |
|
372 |
137 |
Auto reset |
|
373 |
138 |
Spare |
|
374 |
139 |
spare |
|
375 |
140 |
spare |
|
57 |
141 |
E-Stop or Manaul button is pressed
|
|
58 |
142 |
/Open page CTRL+S on plc nr
|
|
51 |
151 |
Unknown string from L0 machine
|
|
52 |
152 |
E-stop or Manu push button is pushed
|
|
534 |
171 |
Left-Front Sensor not working |
|
533 |
172 |
Left-Back Sensor not working |
|
535 |
173 |
Right-Front Sensor not working |
|
536 |
174 |
Right-Back Sensor not working |
|
225 |
181 |
Unkown string from machine |
|
303 |
191 |
Communication Error on Entry PLC |
|
60 |
192 |
PLC communication is resumed
|
|
76 |
200 |
Mission issues
|
|
77 |
201 |
PRQ - Machine is not in Auto mode
|
|
78 |
202 |
PRQ - Machine is busy and not W@R
|
|
79 |
203 |
PRQ - Transfer deck is not at any aisle
|
|
80 |
204 |
PRQ - Transfer deck is not at target aisle
|
|
81 |
205 |
PRQ - Transfer deck entry bay is still full(US cannot do next entry)
|
|
82 |
206 |
PRQ - Transfer deck Exit bay is still full
|
|
83 |
207 |
PRQ - Entry bay for upper shuttle is empty
|
|
84 |
208 |
PRQ - Exit bay for lower shuttle is still full
|
|
85 |
209 |
PRQ - Stacker is in ransit
|
|
86 |
210 |
PRQ - Transfer deck is already in target aisle
|
|
87 |
211 |
PRQ - Shuttle is serving the stacker
|
|
88 |
212 |
PRQ - Transfer deck is in transit
|
|
89 |
213 |
PRQ - Transfer deck is in Manu
|
|
376 |
215 |
Check sum error |
|
377 |
216 |
Spare |
|
378 |
217 |
Spare |
|
379 |
220 |
8200} --- PLC is happy with the message |
|
307 |
221 |
Timeout: Entry PLC did not clear its @F plag after 3 tries by PC |
|
308 |
222 |
Timeout: Exit PLC did not clear its @F plag after 3 tries by PC |
|
309 |
223 |
Entry mission Error: Source = 0 is detected |
|
380 |
230 |
PC did not get a response from PLC |
|
90 |
231 |
Send - failed reset PRQ and reset machine
|
|
91 |
232 |
Send - failed on Transfer deck move. Cencel UDC and reset machine
|
|
92 |
233 |
Send - failed on stacker home. Cancel UDC and report to L2 machine offlined
|
|
93 |
235 |
EXE - UDC is running over 90 secords
|
|
94 |
236 |
EXE - UDC is showing on execution but machine is idling
|
|
95 |
237 |
EXE - Timeout on W@R
|
|
381 |
240 |
Travel (X1) brake did not operate during function run |
|
382 |
241 |
Travel (X2) brake did not operate during function run |
|
383 |
242 |
Hoist (Y) brake did not operate during function run |
|
384 |
243 |
Object on board after Forks extended |
|
385 |
244 |
Cross beam blocked on West (Left) |
|
386 |
245 |
Cross beam blocked on East (Right) |
|
387 |
246 |
The fork is not on center position |
|
388 |
247 |
Object on board after Froks extended |
|
301 |
248 |
No 48" Slave Pallet availalble for pulling |
|
302 |
249 |
No 96" Slave Pallet availalble for pulling |
|
228 |
250 |
@F31 - UDC reported from Machine does not match it's Machine ID inside UDC table |
|
96 |
251 |
@F check - The UDC from L0 is not found in L1 UDC table
|
|
97 |
252 |
@F check - machine # from @F does not machine # on the same UDC
|
|
98 |
253 |
@F check - Reported @F for the UDC is still in PRQ state
|
|
222 |
254 |
@F7 from Q4. No acion taken |
|
223 |
255 |
@F255 reported from CMA |
|
224 |
256 |
@F2 UDC is reset by PC operator |
|
99 |
263 |
@F3 - UDC is aborted
|
|
100 |
264 |
@F4 - NOT used: UDC is cancelled
|
|
101 |
265 |
@F5 - Wrongth pallet length
|
|
102 |
266 |
@F6 - UDC not on aboard
|
|
103 |
267 |
@F7 - US timeout
|
|
104 |
268 |
@F8 - Bay 4 Entry
|
|
105 |
269 |
@F9 - Duplicated UDC
|
|
106 |
270 |
@F10 - @R is rejected - UDC replacement impossible
|
|
107 |
271 |
@F11 - Target cell empty
|
|
108 |
272 |
@F12 - Destination cell full
|
|
109 |
273 |
@F13 - Source # is off range
|
|
110 |
274 |
@F14 - Destination # is off range
|
|
111 |
275 |
@F15 - Source # is disabled
|
|
112 |
276 |
@F16 - Destination # is disabled
|
|
113 |
277 |
@F17 - Wrong machine ID
|
|
114 |
278 |
@F18 - Machine Buffer full
|
|
115 |
279 |
@F19 - Abort UDC from Q4
|
|
116 |
280 |
Spare
|
|
117 |
281 |
L2 Read - Duplicated UDC: L2 UDC is already in L1 UDC table
|
|
118 |
282 |
L2 read - @R UDC from L2 Can not be found in UDC table
|
|
119 |
283 |
Not defined machine for ?C
|
|
120 |
284 |
Illegal stacker #
|
|
389 |
290 |
Communication interrupted |
|
121 |
291 |
not used |
|
122 |
292 |
not used |
|
183 |
293 |
Unrecognizable pallet # at Scanner Q4 |
|
390 |
294 |
OPC communication between PC and SC-6 PLC is resumed |
|
391 |
295 |
Connection between PC20 to L2PC is lost, Click "reconnect DB" function |
|
392 |
296 |
Reconnect database is attampted |
|
393 |
297 |
spare |
|
394 |
298 |
spare |
|
123 |
300 |
Status change
|
|
299 |
301 |
Clear Stacker |
|
395 |
302 |
System Exit |
|
396 |
303 |
UDC restored |
|
397 |
310 |
Undifined PC function |
|
124 |
311 |
@C received from L0
|
|
398 |
312 |
Clear North mission table |
|
399 |
313 |
Clear South mission table |
|
400 |
314 |
Clear Q1 mission table |
|
401 |
315 |
Clear L2 mission table |
|
402 |
316 |
Release sticky pushbuttons |
|
403 |
317 |
Edit abnormal cells list |
|
404 |
318 |
Edit user name list |
|
405 |
319 |
Edit Event list |
|
406 |
320 |
Reconnecting to L2database |
|
125 |
321 |
@B received from L0
|
|
126 |
322 |
@B due to sensor status change
|
|
407 |
323 |
Notice posting |
|
408 |
330 |
Spare |
|
409 |
331 |
Complete UDC by PC user |
|
497 |
332 |
Reset UDC by PC user |
|
498 |
333 |
Abort UDC by PC user |
|
499 |
334 |
Restore UDC from Database |
|
127 |
361 |
AbortB4 received from Upper shuttle
|
|
529 |
371 |
Left-Front Sensor not working |
|
530 |
372 |
Left-Back Sensor not working |
|
531 |
373 |
Right-Front Sensor not working |
|
532 |
374 |
Right-Back Sensor not working |
|
128 |
400 |
Program start
|
|
130 |
401 |
UDC is Completed by User
|
|
131 |
402 |
UDC is Reset by User
|
|
132 |
403 |
UDC is Aborted by User
|
|
133 |
404 |
Rush a UDC for Aisle Change |
|
134 |
405 |
Move UDC to Next Machine |
|
135 |
406 |
Function Move |
|
136 |
407 |
spare |
|
182 |
408 |
spare |
|
137 |
409 |
Minimize program for Windows task |
|
129 |
410 |
Program Quit
|
|
138 |
411 |
Function Stacker: TD Entry to Cell |
|
139 |
412 |
Function Stacker: Cell to TX Exit |
|
140 |
413 |
Function Stacker: Stacker to Cell |
|
141 |
414 |
Function Stacker: Stacker to TD Exit |
|
142 |
415 |
Function Stacker: TD Entry to TD Exit |
|
143 |
416 |
Function Stacker: Clear Stacker Mission
|
|
231 |
417 |
Function Stacker: Tag/Untag Stacker
|
|
232 |
420 |
Function Stacker: Stacker home
|
|
144 |
421 |
Close a TD Entry |
|
145 |
422 |
Open a TD Entry |
|
146 |
423 |
Complete TD aisle change
|
|
147 |
424 |
Abort a Transfer deck Entry mission
|
|
148 |
425 |
Abort a Transfer deck Exit mission
|
|
149 |
426 |
Enable/Disable a TD Entry
|
|
150 |
427 |
@ Executing Exit TD transfer move
|
|
151 |
428 |
@ Executing Transfer deck aisle change move
|
|
288 |
429 |
Aisle Change Request |
|
310 |
430 |
UDC Not Assigned --- Pallet # is missing |
|
152 |
431 |
Complete an Upper shuttle mission
|
|
153 |
432 |
Abort an Upper shuttle mission
|
|
154 |
433 |
@ Executing Upper Shuttle Entry 1A move
|
|
155 |
434 |
@ Executing Upper Shuttle Entry 1B move
|
|
156 |
435 |
@ Executing Upper Shuttle Entry 2A move
|
|
157 |
436 |
@ Executing Upper Shuttle Entry 2B move
|
|
158 |
437 |
@ Executing Upper Shuttle Entry 3A move
|
|
159 |
438 |
@ Executing Upper Shuttle Entry 3B move
|
|
410 |
439 |
Pallet data is processed sucessfully @ South entry 5 |
|
411 |
440 |
North Entry is closed by a PC user |
|
160 |
441 |
Complete a Lower shuttle mission
|
|
161 |
442 |
Abort an on-board Lower shuttle mission
|
|
162 |
443 |
Change shipping bay selection
|
|
163 |
444 |
@ Executing Lower Shuttle Exit move
|
|
164 |
445 |
Abort an on-board Upper shuutle mission
|
|
412 |
446 |
not used |
|
413 |
447 |
spare |
|
414 |
448 |
spare |
|
415 |
449 |
spare |
|
230 |
450 |
*** Insert "Machine Tagout" ***
|
|
165 |
451 |
*** Remove "Machine Tagout" ***
|
|
229 |
452 |
Pause L2 Missions |
|
166 |
453 |
Resume L2 missions
|
|
167 |
454 |
@ Generate an Entry mission
|
|
168 |
455 |
@ Generate an Exit mission
|
|
169 |
456 |
Put L2 missions on Hold
|
|
170 |
457 |
Update all machine status to L2
|
|
171 |
458 |
Reset Database by User
|
|
298 |
459 |
Auto Reset Database |
|
172 |
460 |
Spare
|
|
220 |
461 |
Machine is tagged out |
|
221 |
462 |
Machine is untagged |
|
285 |
464 |
Reset Machine |
|
416 |
465 |
free |
|
227 |
471 |
Reset Communication |
|
272 |
474 |
Manual Reset Machine
|
|
270 |
475 |
Auto Reset CNC fault
|
|
271 |
476 |
Manual Reset Machine
|
|
269 |
477 |
CNC fault out three times. Please check it out. |
|
173 |
491 |
Command machine to Manu mode
|
|
174 |
492 |
Command machine to Auto mode
|
|
175 |
493 |
Command Machine Power on
|
|
176 |
494 |
Command machine power off
|
|
177 |
495 |
Command Reset CNC
|
|
178 |
496 |
Command reset siren
|
|
179 |
497 |
Command Abort
|
|
180 |
498 |
Command redraw
|
|
181 |
499 |
Command reset
|
|
417 |
500 |
$$$ L1 LOG POINT (greater than or negatives) $$$ |
|
418 |
501 |
Encoder fault, put in Manual and Reset. (Position off at source) |
|
419 |
502 |
Encoder fault, put in Manual and Reset. (Position off at destnation) |
|
420 |
600 |
----- MISSION ISSUES ----- |
|
422 |
601 |
The UDC updated from L0 does not exit in Q1 UDC Table |
|
423 |
602 |
A UDC status update is incorrect (@F=0) |
|
500 |
603 |
The Machine ID reported UDC status is not the same as indicated in the UDC table |
|
421 |
605 |
Height check failed at Entry bay |
|
424 |
607 |
Invalid cell # at Entry bay or disabled cell # |
|
425 |
608 |
The UDC was reassigned to a different stacker |
|
426 |
609 |
Front sensor blocked while trying to reach the back |
|
427 |
610 |
The UDC from L2 is already in L1 mission table |
|
428 |
611 |
Target Cell Empty --- Pallet missing @ Cell |
|
429 |
612 |
Full on Full --- Pallet unknown @ Cell |
|
430 |
613 |
Target Cell Empty --- Pallet not present at Cell |
|
431 |
615 |
UDC transfer from PC20 to Simotion cannot be completed |
|
432 |
616 |
The reassigned UDC cannot find its original UDC |
|
433 |
617 |
A UDC status update cannot find itself in L1 UDC Table |
|
434 |
631 |
UDC delay --- Stacker in Manu mode. Waiting time = |
|
435 |
632 |
UDC delay --- Stacker Busy. Waiting time = |
|
436 |
634 |
UDC dealy --- Exit bay not ready. Waiting time = |
|
437 |
636 |
UDC delay --- PC/PLC (OPC) transfer. Sendinging time = |
|
438 |
637 |
UDC delay --- Execution. Running time = |
|
439 |
638 |
UDC delay --- Wating for a replacement. Running time = |
|
440 |
650 |
UDC sent to Q3 was not recognized by Q3 |
|
441 |
651 |
UDC update from by Q3 cannot find itself in Exit/Ship UDC table |
|
442 |
660 |
Spare |
|
443 |
661 |
Spare |
|
444 |
662 |
Spare |
|
445 |
663 |
Spare |
|
446 |
664 |
Spare |
|
447 |
665 |
Spare |
|
448 |
700 |
----- PC FUNCTIONS ----- |
|
449 |
701 |
Moved pallet from Entry bay to Cell |
|
450 |
702 |
Moved pallet to Exit bay from Cell |
|
451 |
703 |
Moved pallet from Stacker to Cell |
|
452 |
704 |
Moved pallet to Exit bay from Cell |
|
453 |
705 |
Moved pallet on stacker to Exit bay |
|
454 |
706 |
Moved pallet to Return bay 41 from Cell |
|
455 |
707 |
Moved pallet to Return bay 42 from Cell |
|
456 |
708 |
Moved pallet from Cell to Cell |
|
457 |
709 |
Inspecte pallet at cell by ASH |
|
458 |
710 |
Return pallet the original cell |
|
459 |
711 |
Move Pallet from Entry Bay to Exit bay |
|
460 |
712 |
Clear the Mission inside Stacker |
|
461 |
713 |
*** Tagout Machine *** |
|
462 |
714 |
*** Remove Machine Tag *** |
|
463 |
715 |
spare |
|
496 |
716 |
spare |
|
464 |
724 |
Query Machine status Q3 (Exit and Ship) |
|
465 |
725 |
Query Machine status Q2 (Entry Low and High) |
|
466 |
726 |
Query Shipping Bay status |
|
467 |
727 |
Flush Serial Port |
|
468 |
731 |
Restart a pallet (UDC) at a different Table |
|
469 |
732 |
Reassign a pallet (UDC) to a different stacker |
|
470 |
733 |
Rescan the pallet under scanner by PC |
|
471 |
734 |
Reset UDC # on a table |
|
472 |
735 |
A North Entry Bay is closed |
|
473 |
736 |
A North Entry Bay is Opened |
|
501 |
737 |
Hand scanner scan sucessful |
|
474 |
741 |
Request a South entry 1 mission to L2 |
|
475 |
742 |
Request a South entry 5 mission to L2 |
|
476 |
750 |
Stacker is Offlined |
|
477 |
751 |
Initiate a slave apllet return mission |
|
478 |
752 |
Spare |
|
479 |
753 |
Spare |
|
480 |
800 |
----- operation ----- |
|
481 |
831 |
Pallet in position for barcode scan |
|
482 |
832 |
Barcode scan successful |
|
483 |
833 |
Overhead scanner cannot read this pallet, rescan... |
|
484 |
834 |
Hand-held scanner successful |
|
502 |
835 |
Wating for Hand-held scanner ... |
|
503 |
836 |
Ready for UDC assignment ... |
|
504 |
837 |
No Stacker and Entry Bay is available for UDC assignment. Please wait... |
|
553 |
838 |
No cells avalable for South entry |
|
508 |
839 |
... |
|
505 |
840 |
Requesting a new entry UDC |
|
506 |
843 |
Waiting for UDC assignment |
|
507 |
844 |
Waiting for PLC acknowledgement |
|
509 |
845 |
... |
|
287 |
901 |
Pallet bypassed at Entry |
|
278 |
903 |
UDC aborted by manually removing the pallet out of Entry table |
|
297 |
911 |
No empty cell is available for US entry |
|
275 |
912 |
No empty cell is available for Q4 entry |
|
291 |
913 |
Stacker or TD is not available for Entry (full cell) |
|
292 |
914 |
Stacker or TD is not available for Entry (half cell) |
|
293 |
915 |
Stacker or TD is not available for Entry, Please wait for reassignment. |
|
312 |
916 |
No empty cell is available for Slave pallet entry |
|
313 |
917 |
Stacker or TD is not available for Slave Entry (full) |
|
314 |
918 |
Stacker or TD is not available for Slave Entry (half) |
|
274 |
921 |
Pallet/Order # issue in Opreation Database. Reset Database Under Datalog Menu to retry. |
|
277 |
922 |
Pallet Rejected: Pallet Net Weight = 0 |
|
276 |
923 |
Pallet Rejected: Pallet Grade = "R" |
|
289 |
925 |
Converted Reel # into Pallet # |
|
300 |
926 |
Pallet number re-scaned |
|
315 |
931 |
No cell available for regular pallet entry |
|
316 |
932 |
No cell available for Slave pallet entry |
|
317 |
933 |
No cell available for Resin or End board pallet entry |
|
286 |
941 |
Pallet bypassed |
|
281 |
991 |
Pallet rejected --- Profile check East |
|
282 |
992 |
Pallet rejected --- Profile check West |
|
283 |
993 |
Pallet rejected --- Profile check North |
|
284 |
994 |
Pallet rejected --- Profile check South |
|
280 |
998 |
Entry Stop. Please use function to Reset Q4 |
|
279 |
999 |
Pallet rejected due to profile check failure |
|
203 |
1001 |
No stacker is available for Entry mission |
|
204 |
1002 |
No enpty cell is available for Entry mission |
|
205 |
1004 |
Scanner cannot read this pallet. Please key in the pallet number |
|
206 |
1005 |
Manual Pallet # |
|
290 |
1006 |
Mixed Coupling Assigned due to No Empty Cell |
|
311 |
1007 |
No record for update |
|
294 |
1012 |
No Cell available for Replacement. Use function to move the pallet out. |
|
215 |
1101 |
Pallet Rejected: The Pallet Not Exist in Opreation Database |
|
216 |
1102 |
Pallet Rejected: Pallet Net Weight = 0 |
|
217 |
1103 |
Pallet Rejected: Pallet Grade = "R" |
|
208 |
1104 |
Manual Entry replacement mission from Bay 4 |
|
207 |
1105 |
Manual mission |
|
268 |
1109 |
Pallet Bypassed by Operator |
|
226 |
1113 |
Entry Pallet Length out of Range |
|
209 |
1201 |
Pulling pallets |
|
543 |
1202 |
The pallet # not exist |
|
211 |
1205 |
Disable cell by user |
|
210 |
1211 |
Edit cell table by user |
|
212 |
1212 |
Edit cell group by user
Edit cell group |
|
213 |
1213 |
Delete pallet record by user |
|
214 |
1214 |
Group edit pallets by user |
|
273 |
1215 |
Edit Production pallet record |
|
552 |
2001 |
delete a udc from database |
|
510 |
9011 |
JR shuttle going to XE01 |
|
511 |
9012 |
JR shuttle going to XE02 |
|
512 |
9013 |
JR shuttle going to XE03 |
|
513 |
9014 |
JR shuttle going to XE04 |
|
514 |
9015 |
JR shuttle going to JR warehouse |
|
515 |
9016 |
Clear all functions |
|
516 |
9063 |
Get sation data from XS12 |
|
517 |
9064 |
Send data to Ergon XS12 |
|
518 |
9073 |
Read station data from XS13 |
|
519 |
9074 |
Send Reel data to Ergon XS13 |
|
523 |
9081 |
A New Jumbo Roll is Selected |
|
528 |
9082 |
Mahicne is Running |
|
520 |
9083 |
Transfer Goebel data to Bonfanti |
|
521 |
9084 |
Generate Reels Records for Labeling |
|
527 |
9085 |
Duplicate download from Goebel |
|
546 |
9086 |
No yield for weight calculation |
|
547 |
9087 |
Doff_no already exist. No new reel records created. |
|
548 |
9088 |
Created reel records manually |
|
522 |
9801 |
Database Error/Reset |
|
545 |
9810 |
Charting data is sent to Geobel |
|
524 |
9811 |
Reel ID sent to Printer PC is not valid |
|
525 |
9812 |
Reel Label being Printed |
|
541 |
9813 |
Manual Print |
|
526 |
9814 |
Illegal Reel ID detected |
|
549 |
9815 |
Edit Reel width for Goebel Chart |
|
550 |
9816 |
Reel length is too large, use chart length instead |
|
551 |
9817 |
Manual reel width correction |
|