| 805 |
BOPP_1 |
Pallet not transferring onto upper shuttle |
Got called from Rey pallet island BOPP 1 he said that there was a twisted pallet on shuttle so he took down aborted mission and shuttle then he sent another pallet up and that shuttle would not pick up. So when I get here and I as well tried to abort everything and nothing happened well the program still showed that there was a pallet on shuttle. Is all I did was restart the program and pallet went away sent another up and worked. Follow up: find out why when you abort shuttle it does not remove pallet. |
2025-03-19 08:08:53 |
Not Assigned |
|
| 812 |
BOPP_2 |
Called from BOPP2 Crane4 Height position sensor not making |
Came adjusted bracket because sensor was move all the way down already so move bracket about 1/4 inch up so sensor will make and checked distance to cantalever looked good back to auto watched mission good |
2025-03-22 19:11:20 |
Not Assigned |
|
| 814 |
BOPP_1 |
Got called packing cranes would not open |
Troubleshooting for awhile but did not fix left down moved back up to 13 for them to use Folow up check packing 14 for not opening |
2025-03-23 20:38:15 |
Not Assigned |
|
| 815 |
CFP |
Got called that pallets stoping in middle of conveyor adjusted sensor seemed to work then gearbox sounded funny |
Found gearbox making noise but still moving also cutting arm clamp needs to be replaced Follow up change gearbox and install clamp for cutting arm |
2025-03-23 20:41:54 |
Not Assigned |
|
| 816 |
CFP |
Got called that pallets stoping in middle of conveyor adjusted sensor seemed to work then gearbox sounded funny |
Found gearbox making noise but still moving also cutting arm clamp needs to be replaced Follow up change gearbox and install clamp for cutting arm |
2025-03-23 20:41:57 |
Not Assigned |
|
| 822 |
BOPP_2 |
operator report saying no power on panel and cant not power up doing reset
found dust accumulate inside busbar |
found main braker on mcc room re set power up and ready for auto
need to blow busbar dust out for better function |
2025-04-01 07:57:34 |
Not Assigned |
|
| 830 |
BOPP_1 |
cpu keep going into reset |
CHAGE OUT CPU, CHANGE OUT POWER SUPPLY ,CHECK RELAY CUBES |
2025-04-30 08:39:10 |
Not Assigned |
|
| 835 |
BOPP_1 |
call in: shuttle will not move |
remove chain so they can push shuttle. but could not because of damaged cable carrier. |
2025-05-27 07:50:18 |
Not Assigned |
|
| 842 |
BOPP_1 |
Call in. East cradle core sensor damaged and bolts for Teflon block broken |
Replace broken sensor and bolts
Follow up. 1. Selicon wire.
2. Spare parts. Sensor and bolts. |
2025-06-05 07:20:46 |
Not Assigned |
|
| 843 |
BOPP_1 |
Call but did not come in. Operator said there is no light on c and y lazer encoder told him to leave down. |
Follow up |
2025-06-05 07:23:14 |
Not Assigned |
|
| 848 |
BOPP_2 |
crane 2 would not run any global mission due to crane 3 showing offline and was dead had no power |
check on board panel, rebooted , bypass crane 3 so crane 2 could run manually and global
could use arms manually |
2025-06-18 07:54:00 |
Not Assigned |
|
| 855 |
BOPP_1 |
bopp1 stacker 3 tore up tranferdeck 3 back stop and fork sensor |
tack welded back stop and fork sensor bracket |
2025-07-23 20:51:13 |
Not Assigned |
|
| 856 |
BOPP_1 |
crane would not power up |
cpu keeps going into reset |
2025-07-24 08:57:12 |
Not Assigned |
|
| 862 |
BOPP_1 |
got call from rosa pallet entry operator from bopp1 she describe that the previews operator dot leave a note of the situation she cant not send up 48s only 96s pallets |
if she send 48s pallets the system report is a 96 i check all the sensors and was good all of them |
2025-08-23 02:49:36 |
Not Assigned |
|
| 863 |
BOPP_1 |
operator from pallet island report saying that having problems with the wrapper sense friday
bopp1 from 6:00 to 8:00 |
i re set a inverter that has alarm on it try on auto works good it wrap 7 pallets after that the machine go in to alarm with no codes on screen |
2025-08-23 19:49:53 |
Not Assigned |
|
| 873 |
BOPP_1 |
Got called that stacker 2 was in high position in transfer deck and could not recover |
When I got here looked for y position wire number 429 and jumped it with 24v+ wire number 3 so I could move the stacker out of transfer deck ounce out lowered stacker platform reset then back to auto stacker came into transfer deck but did not drop pallet off so took off manually clear missions then back to auto it ran for awhile I had already left and got called that it was at the lower position limit now so checked wires and when i would tug on wire module would reset so took wires number 428 re-stripped them put back and tighten terminal block it was stable watched missions looked good |
2025-09-30 08:04:32 |
Not Assigned |
|
| 877 |
BOPP_2 |
J/R shuttle stopping short |
Got called back because it was doing it again when I got here I was texting with Thomas and the settings that were entered were temporary so when they reset power they went back to original settings Thomas did some other changes to settings to make work and permanent for the night I stayed and watched several missions this time and it looked stable so I left did not get a call for the rest of the night for J/R shuttle |
2025-10-06 07:20:05 |
Not Assigned |
|
| 878 |
BOPP_1 |
Monitor on line 4 for panel turning off |
Came in Saturday to work on line 12 project before I got here Alex had called for line 4 monitor turning off so I went to check and sure enough it was off so I moved the plug for monitor and it stayed on, 15 min later Alex called back said it did it again so went back and this time tightened the terminals for plug in back of monitor seemed to work, I did not get call back on it until Monday morning at 5 so I came in moved wires behind easy chassis and it came on watched them roll out and seemed stable for now next roll out is at 8AM |
2025-10-06 07:35:43 |
Not Assigned |
|
| 879 |
BOPP_1 |
operator JAVIER call to report that line #14 shuttle don't able to operate eater manual or automatic |
# 1 found backer trip #QM35 2 inside the panel
# 2 found pipe has drop on top of sensor
# 3 east top push by stock of wood embors
re set panel after and get it back on auto
need to build guards around to protect sensors and the equipment |
2025-10-08 02:24:27 |
Not Assigned |
|
| 881 |
CFP |
stacker would not go into auto |
would move mauly up and down and forks go east and west |
2025-11-03 10:51:45 |
Not Assigned |
|